SPECIFICATIONS | |||||||
AC Volts (40 Hz to 500Hz) *1 | Range | Resolution | Accuracy | ||||
6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 1.0 % + 3 | |||||
DC Volts | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 0.5 % + 3 | ||||
AC Millivolts *2 | 600.0 mV | 0.1 mV | 3.0 % + 3 | ||||
Diode Test | 2.000 V | 0.001 V | 10 % | ||||
Resistance (Ohms) | 400.0 ? 4.000 k? 40.00 k? 400.0 k? 4.000 M? 40.00 M? | 0.1 ? 0.001 k? 0.01 k? 0.1 k? 0.001 M? 0.01 M? | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 | ||||
Capacitance *3 | 50.00 nF 500.0 nF 5.000 ?F 50.00 ?F 500.0 ?F 1000 ?F | 0.01 nF 0.1 nF 0.001 ?F 0.01 ?F 0.1 ?F 1 ?F | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | ||||
Frequency *4 Hz (10 Hz ? 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | 0.1 % + 3 | ||||
Duty Cycle *4 | 1 % to 99 % | 0.1 % | 1 % typical *5 | ||||
AC Current (40 Hz to 200 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | ||||
DC Current | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | ||||
Note : *
|
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC Volts | 600 V 1 | >10 M? <100 pF 2 | >60 dB at dc, 50 Hz or 60 Hz | - |
AC Millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
DC Volts | 600 V 1 | >10 M? <100 pF | >100 dB at dc, 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
Note : *
|
General Specifications | |
Maximum Voltage Between any Terminal and Earth Ground | 600 V |
Display (LCD) | 6000 counts, updates 3/sec |
Battery Type | 2 AAA, NEDA 24A, IEC LR03 |
Battery Life | 200 hours minimum |
Temperature | |
Operating | 0 ?C to 40 ?C |
Storage | -30 ?C to 60 ?C |
Relative Humidity | |
Operating Humidity | Non-condensing when <10?C ?90 % at 10 ?C to 30 ?C; ?75 % at 30 ?C to 40 ?C |
Operating Humidity, 40 M? Range | ?80 % at 10 ?C to 30 ?C; ?70 % at 30 ?C to 40 ?C |
Altitude | |
Operating | 2000 m |
Storage | 12,000 m |
Temperature Coefficient | 0.1 X (specified accuracy) /?C (<18 ?C or >28 ?C) |
Fuse Protection for Current Inputs | 11A, 1000V Fast Fuse, Fluke specified part only |
Size (HxWxL) | 142 mm x 69 mm x 28mm |
Weight | 200 g |
IP Rating | IEC 60529: IP 40 |
Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 |
Electromagnetic Environment | IEC 61326-1: Portable |
Electromagnetic Compatibility | Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment) *1 |
Note : * 1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. |