SPECIFICATIONS
Country of OriginUSA
Dimension (H x W x L)22.2 cm x 10.2 cm x 6 cm
Weight871 g
Voltage DCAccuracy0.025 %
Range and Resolution50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage ACAccuracy0.4 %(true-rms)
Range and Resolution50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DCAccuracy0.06 %
Range and Resolution500.00 ?A, 5000.0 ?A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current ACAccuracy0.61 %(true-rms)
Range and Resolution500.00 ?A, 5000.0 ?A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature (excluding probe)Accuracy1.0 %
Range and Resolution-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
ResistanceAccuracy0.05 %
Range and Resolution500.00 ?, 5.0000 k?, 50.000 k?, 500.00 k?, 5.0000 M?, 50.00 M?, 500.0 M?
Resistance 10 50 ? (2 wire connection)Accuracy0.15 % + 20
Range and resolution50.000 ?
CapacitanceAccuracy1.0 %
Range and Resolution1.000 nF,10.00 nF 100.0 nF, 1.000 ?F, 10.00 ?F, 100.0 ?F, 1000 ?F, 10.00 mF, 100.00 mF ?
FrequencyAccuracy0.005% + 5
Range and Resolution99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/featuresMultiple on-screen displaysYes
True-rms AC bandwidth100 kHz
DBV/dBmYes
DC mV resolution1 ?V
Megohm rangeUp to 500 M
Conductance50.00nS
Continuity beeperYes
Battery/Fuse accessBattery / Fuse
Peak250 S
Elapse time clockYes
Time of day clockYes
Min-Max-AvgYes
FrequencyYes
Duty Cycle0.01 % to 99.99 %
Pulse Width0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
HoldYes
Isolated Optical InterfaceYes
Auto/Touch HoldYes
Reading memoryYes
Log to PCYes
Interval/Event LoggingYes
Logging MemoryUp to 10,000 readings
Resistance Low Ohm0.001 ? to 50.000 ? 10 mA source
LoZYes
Low Pass FilterYes
Environmental
Operating Temperature-20 °C to +55 °C
Storage Temperature-40 °C to +60 °C
Relative Humidity0% to 90% (0 °C - 37 °C)
0% to 65% (37 °C - 45 °C),
0 to 45 % (45 °C - 55 °C
Electromagnetic CompatabilityEMC EN6 1326-1
VibrationRandom vibration per MIL-PRF-28800f Class 2
Shock1 meter drop per IEC/EN 61010-1 2nd edition
Safety
Overvoltage categoryCAT III 1000 V / CAT IV 600 V safety rated
Agency ApprovalsCSA, UL, TÜV, CE
Mechanical & General
Maximum voltage between any terminal and earth ground1000V
Battery Life100 minimum, 200 hours in logging mode
Battery type6 AA alkaline batteries, NEDA 15A IEC LR6