FLUKE 1653B-08 Installation Tester with Autotest

Share to:
Merek: Fluke | | 0 Orders

<% k.charAt(0).toUpperCase()+k.slice(1) %>
0 Seller(s) selling this item.

<% v.item_name %>

Merek: Fluke

<% v.total_order_items %> Orders

Sold by

<% v.name_shop %>

<% v.province_name %>


Quantity :
Minimum Quantity:
<% v.minimum_order %>
Price :
Rp <% v.retail_price | rupiah %>
<% v.retail_discount ? "Discount " : "" %>Price :
Rp <% v.price | rupiah %>
-<% v.retail_discount_percentage %>%

 

SPECIFICATIONS
Country of originUSA
Dimension (L x W x H)10 x 25 x 12.5 cm
Weight1.3 kg
BatteriesType AA: 6
Battery typeAlkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries
Model1653B
AC Voltage MeasurementRange: 500 V
Resolution:  0.1 V
Accuracy (50 - 60 Hz) :  ± (0.8% + 3 digits)
Input Impedance : 3.3 M?
Overload Protection : 660 Vrms
Continuity TestingRange (autoranging):  20 ?, 200 ?, 2000 ?
Resolution: 0.01 ?, 0.1 ?, 1 ?
Test Current: > 200 mA
Open Circuit Voltage: > 4 V
Accuracy: ± (1.5%+3 digits)
Insulation Resistance MeasurementTest Voltage:  250 - 500 - 1000 V

Test Voltage: 50 V Test Current: 1 mA @ 50 k?
Insulation Range: 10 M?/50 M?
Resolution: 0.01 M?
Accuracy: ± (3% + 3 digits)

Test Voltage: 100 V
Test Current: 1 mA @ 100 k?
Range/Resolution: 20 M?/0.01 M?
Range/Resolution: 100 M?/0.1 M?
Accuracy: ± (3% + 3 digits)

Test Voltage: 250 V
Test Current: 1 mA @ 250 k?
Range/Resolution: 20 M?/0.01 M?
Range/Resolution: 100 M?/0.1 M?
Accuracy: ± (1.5% + 3 digits)

Test Voltage: 500 V
Test Current:  1 mA @ 500 k?
Range/Resolution: 20 M?/0.01 M?
Range/Resolution: 200 M?/0.1 M?
Accuracy: ± (1.5% + 3 digits)
Range/Resolution: 500 M?/1 M?
Accuracy: 10%

Test Voltage: 1000 V
Test Current: 1 mA @ 1 M?
Range/Resolution: 20 M?/0.01 M?
Range/Resolution: 200 M?/0.1 M?
Accuracy: ± (1.5% + 3 digits)
Range/Resolution: 500 M?/1 M?
Accuracy: 10%

Auto Discharge: Discharge time constant, 0.5 second for C = 1 µF or less
Live Circuit Detection: Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum Capacitive Load: Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode)Range:  100 - 500 VAC (50/60 Hz)
Input connection: Soft Key selection
Loop impedance: Phase to earth
Line impedance: Phase to neutral
Limit on consecutive tests: Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)

Max. Test Current. High Current and Non-Trip Modes:
Maximum Test Current @ 400 V: 20 A sinusoidal for 10 ms
Maximum Test Current @ 230 V:Maximum Test Current @ 230 V: 12 A sinusoidal for 10 ms

Range/Resolution: 20 ?/0.01 ?
Range/Resolution: 200 ?/0.1 ?
Range/Resolution: 2000 ?/1 ?

Accuracy (no Trip mode): ± (3% + 6 digits)
Accuracy (Hi Current mode): ± (2% + 4 digits)
PFC, PSC TestComputation: PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range: 0 - 25 kA
Resolution (Ik < 1000 A): 1 A
Resolution (Ik >= 1000 A): 0.1 kA
Accuracy: Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹G: General, no delay
S: Time delay
A: Responds to pulsed signal
AC: Responds to AC
Tripping Time Test (?T)Trip Time Accuracy:  ±(1% Reading + 1 digit)
Multiplier: x ½
Current Settings: 10, 30, 100, 300, 500, 1000 mA
Current Accuracy: +0% - 10%
RCD Type ¹: G
Measurement Range: 310 ms (Europe), 2000 ms (UK)
RCD Type ¹: S
Measurement Range: 510 ms (Europe), 2000 ms (UK)

Multiplier: x 1
Current Settings: 10, 30, 100, 300, 500, 1000 mA
Current Accuracy: +10% - 0%
RCD Type ¹: G
Measurement Range: 310 ms
RCD Type ¹: S
Measurement Range: 510 ms

Multiplier: x 5
Current Settings:  10, 30 mA
Current Accuracy: ±10%
RCD Type ¹: G
Measurement Range: 50 ms
RCD Type ¹: S
Measurement Range: 160 ms
Tripping Current (ramp)Current Range: 50% - 110% of RCD's rated current
Step Size: 10% of I?N
Dwell time (Type G)¹: 300 ms / step
Dwell time (Type S)¹: 500 ms / step
Trip Current Measurement Accuracy: ±5%
Earth Resistance Test (RE)Range/Resolution:: 200 ?/0.1 ?
Accuracy: ±(2% + 5 digits)
Range/Resolution: 2000 ?/1 ?
Accuracy: ±(3.5% + 10 digits)
Frequency: ± 128 Hz
Compliance Voltage: +25 V
Phase Sequence IndicationIcon:  Icon Phase Sequence indicator is active
Display of Phase Sequence: Displays '1-2-3' in digital display field for correct sequence. Displays '3-2-1' for incorrect phase. Dashes in place of a number indicate a valid determination could not be made.
Environmental
Operating Temperature-10 °C to 40 °C
Humidity (Without Condensation)10 to 30 °C:  95%
30 to 40 °C: 75%
Safety
Safety Rating EN 61010-I CAT III 500V, CAT IV 300V