FLUKE 1587 Insulation Tester Multimeter Digital
FLUKE 1587 Insulation Tester Multimeter Digital
Waspada Penipuan
Hati-hati terhadap penipuan yang mengatasnamakan Ralali. Pastikan hanya mengakses Ralali.com atau hubungi 0818-500-465 untuk konfirmasi. Info lebih lanjut, Klik Disini
SPECIFICATIONS | |||
| Country of Origin | USA | ||
| Dimension (H x W x L) | 203 x 100 x 50 mm (with holster) | ||
| Voltage DC | Maximum voltage | 1000 V | |
| Accuracy | ±(0.09% + 2) | ||
| Maximum resolution | 0.001 V | ||
| Voltage AC | Maximum voltage | 1000 V | |
| Accuracy | ±(2% + 3) | ||
| AC bandwidth | 5 kHz1 | ||
| 1. with low pass filter; 3 db @ 800 Hz | |||
| Maximum resolution | 0.1 mV | ||
| Current DC | Maximum amps | 400 mA | |
| Amps accuracy | ±(0.2% + 2) | ||
| Maximum resolution | 0.01 mA | ||
| Current AC | Maximum amps | 400 mA | |
| Amps accuracy | ±(1.5% + 2)2 | ||
| 2. 1 kHz bandwidth | |||
| Maximum resolution | 0.01 mA | ||
| Resistance | Maximum resistance | 50 M? | |
| Accuracy | ±(0.9% + 2) | ||
| Maximum resolution | 0.1 ? | ||
| Capacitance | Maximum capacitance | 9,999 µF | |
| Accuracy | ±(1.2% + 2) | ||
| Maximum resolution | 1 nF | ||
| Frequency | Maximum frequency | 100 kHz | |
| Accuracy | ±(0.1% + 1) | ||
| Maximum resolution | 0.01 Hz | ||
| Temperature Measurement | -40.0°C to 537°C | ||
| -40.0°F to 998°F excluding probe | |||
| Diode test | Range/Resolution | 6 V / 1 mV | |
| Accuracy | ±(2% + 1) | ||
| Insulation Test | |||
| Minimum test current @ 1k?/V | 1 mA | ||
| Test Voltages | 50, 100, 250, 500, 1000 V | ||
| Maximum resistance per test voltage | 50 V | ||
| 100 V | |||
| 250 V | |||
| 500 V | |||
| 1000 V | 2 G? | ||
| Maximum resolution per test voltage | 50 V | 0.01 M? | |
| 100 V | 0.01 M? | ||
| 250 V | 0.1 M? | ||
| 500 V | 0.1 M? | ||
| 1000 V | 0.1 M? | ||
| Accuracy per test voltage | 50 V | ±(3% + 5) | |
| 100 V | ±(3% + 5) | ||
| 250 V | ±(1.5% + 5) | ||
| 500 V | ±(1.5% + 5) | ||
| 1000 V | ±(1.5% + 5) to 600 M?, ±(10% + 3) above 600 M? | ||
| Environmental Specifications | |||
| Operating temperature | –20°C to +55°C | ||
| Storage temperature | -40°C to +60°C | ||
| Humidity (without condensation) | 0% - 95% (10°C – 30°C) | ||
| 0% - 75% (30°C – 40°C) | |||
| 0% - 40% (40°C – 55°C) | |||
| Operating altitude | 2000 m | ||
| Safety Specifications | |||
| Overvoltage category | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V | ||
| Agency approvals | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V | ||
| Mechanical and General Specifications | |||
| Weight | 624 g | ||
| Warranty | 3 years | ||
| Battery life alkaline | Meter use | 1000 hours | |
| Insulation test u6se | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M? with a duty cycle of 5 seconds on and 25 seconds off. | ||
| IP rating | IP40 | ||