SPECIFICATIONS | ||
Country of Origin | USA | |
Size | 50 x 100 x 203 mm (1.25" H x 3.41"L x 7.35" W) | |
Weight | 610 g (1.6 lbs) | |
Current Measurement | Range: 0-1 A AC or DC Resolution: 1 mA Accuracy: 0.2% + 2 LSD (DC) Range: 0-30 mA Resolution: 0.001 mA Accuracy: 0.05% + 2 LSD | |
Current Sourcing | Range: 0-20 mA or 4-20 mA Resolution: 0.05% of span Drive Capability: 24 V Compliance or 1200 ? @ 20 mA | |
Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
Continuity | Beeps for resistance < 100 ? | |
Voltage measurement | Range: 0-1000 V AC (true-rms) or DC Resolution: 0.1 mV to 1.0 V Accuracy: 0.1% Rdg + 1 LSD (VDC) | |
Resistance measurement | to 40 M?, 0.2% + 1 LSD | |
Diode test | 2.0 V shows diode voltage drop | |
Display current and % of span | Yes | |
Auto step, auto ramp | Yes | |
Operating Temperature | -20 ?C to 55 ?C | |
Storage Temperature | -40 ?C to 60 ?C | |
Humidity (Without Condensation) | 95% up to 30 ?C 75% up to 40 ?C 45% up to 50 ?C 35% up to 55 ?C | |
Temperature Coefficient | 0.05 x (specified accuracy) per ?C (for temperatures < 18 ?C or > 28 ?C) | |
Electrical Safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 | |
Overvoltage category | IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V | |
Maximum voltage | 1000 V rms | |
Batteries | 4 AA Alkaline batteries | |
Battery Life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
Shock & Vibration | Random, 2 g, 5-500 Hz 1 meter drop test |