Temperature Sensor
Range: -20 to 70C (-4 to 158F)
Accuracy: 0.21C from 0 to 50C (0.38F from 32 to 122F)
Resolution: 0.024C at 25C (0.04F at 77F)
Response time: 6 minutes in air moving 1 m/s (2.2 mph)
Drift: 0 .1C (0.18F) per year
RH Sensor
Range: 1% to 100% RH at -40 to 75C (-40 to 167F), non-condensing; exposure to conditions below -20C (-4F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1%
Accuracy:2.5% from 10% to 90% RH typical to a maximum of 3.5% including hysteresis at 25C (77F); below 10% and above 90% 5% typical
Resolution: 0.05%
Response time: 5 minutes to 90% in airflow of 1 m/s (2.2 mph)
Drift: 1 % per year typical
Cable length: 1.83 m (6 ft)
Logger
Logger Operating Range
Logging: -20 to 70C (-4 to 158F); 0 to 95% RH (non-condensing)
Launch/readout: 0 to 50C (32 to 122F) per USB specification
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time accuracy: 1 minute per month at 25C (77F)
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: One 3V CR2032 lithium battery
Memory: 128 KB (84,650 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 20 seconds
LCD: LCD is visible from: 0 to 50C (32 to 122F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 8.48 x 2.29 cm (1.44 x 3.34 x 0.9 in.)
Weight: 30 g (1.06 oz)
Environmental rating: IP50